Papers › Support vector machine based arrhythmia classification using reduced features

Support vector machine based arrhythmia classification using reduced features

1 Jan 2005International Journal of Control, Automation, and Systems 2005 1archive 2025-07-28

Mi Hye Song, Jeon Lee, Sung Pil Cho, Kyoung Joung Lee, Sun Kook Yoo

In this paper, we proposed an algorithm for arrhythmia classification, which is associated with the reduction of feature dimensions by linear discriminant analysis (LDA) and a support vector machine (SVM) based classifier. Seventeen original input features were extracted from preprocessed signals by wavelet transform, and attempts were then made to reduce these to 4 features, the linear combination of original features, by LDA. The performance of the SVM classifier with reduced features by LDA showed higher than with that by principal component analysis (PCA) and even with original features. For a cross-validation procedure, this SVM classifier was compared with Multilayer Perceptrons (MLP) and Fuzzy Inference System (FIS) classifiers. When all classifiers used the same reduced features, the overall performance of the SVM classifier was comprehensively superior to all others. Especially, the accuracy of discrimination of normal sinus rhythm (NSR), arterial premature contraction (APC), supraventricular tachycardia (SVT), premature ventricular contraction (PVC), ventricular tachycardia (VT) and ventricular fibrillation (VF) were 99.307%, 99.274%, 99.854%, 98.344%, 99.441% and 99.883%, respectively. And, even with smaller learning data, the SVM classifier offered better performance than the MLP classifier.

PaperPDF

Code

No code repository is listed for this paper in the archive or in Syntology's graph.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Arrhythmia DetectionClassificationElectrocardiography (ECG)General ClassificationRhythm

Results from the paper archive 2025-07-28

TaskDatasetModelMetricValueRank at snapshotLeaderboardReport
Arrhythmia Detection MIT-BIH AR SVM Accuracy (Inter-Patient) 76.3% #6 of 6 Archive leaderboard report
Arrhythmia Detection MIT-BIH AR SVM Accuracy (Intra-Patient) 98.7% #6 of 6 Archive leaderboard report

Ranks are positions in the archive's leaderboards as they stood at the 2025-07-28 snapshot. Results published since then are not among these rows, so a rank here is not a current standing.

Methods

LDASVM