Papers › Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation

Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation

27 Apr 2020arXiv:2004.12537archive 2025-07-28

Jun Ma, Yixin Wang, Xingle An, Cheng Ge, Ziqi Yu, Jianan Chen, Qiongjie Zhu, Guoqiang Dong, Jian He, Zhiqiang He, Yuntao Zhu, Ziwei Nie, Xiaoping Yang

Purpose: Accurate segmentation of lung and infection in COVID-19 CT scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radiologists are busy fighting the coronavirus disease. Furthermore, it is hard to compare current COVID-19 CT segmentation methods as they are developed on different datasets, trained in different settings, and evaluated with different metrics. Methods: To promote the development of data-efficient deep learning methods, in this paper, we built three benchmarks for lung and infection segmentation based on 70 annotated COVID-19 cases, which contain current active research areas, e.g., few-shot learning, domain generalization, and knowledge transfer. For a fair comparison among different segmentation methods, we also provide standard training, validation and testing splits, evaluation metrics and, the corresponding code. Results: Based on the state-of-the-art network, we provide more than 40 pre-trained baseline models, which not only serve as out-of-the-box segmentation tools but also save computational time for researchers who are interested in COVID-19 lung and infection segmentation. We achieve average Dice Similarity Coefficient (DSC) scores of 97.3\%, 97.7\%, and 67.3\% and average Normalized Surface Dice (NSD) scores of 90.6\%, 91.4\%, and 70.0\% for left lung, right lung, and infection, respectively. Conclusions: To the best of our knowledge, this work presents the first data-efficient learning benchmark for medical image segmentation and the largest number of pre-trained models up to now. All these resources are publicly available, and our work lays the foundation for promoting the development of deep learning methods for efficient COVID-19 CT segmentation with limited data.

PaperPDFCodeCode Syntology ran

In Syntology Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, Syntology's MCP tool lists every function and class Syntology harvested from this paper and whether it ran (how to connect): get_harvested_code_for_paper(arxiv_id="2004.12537")

Code

Syntology Ran 0 of 3 code samples harvested from 1 repository linked to this paper; 3 have no recorded run.

By repository: community (archive-listed): 3 samples from 1 repository, 0 ran. The run record, sample by sample. “Ran” means executed on a synthesized input, not that the code is correct or reproduces the paper.

HzFu/COVID19_imaging_AI_paper_list officialmentioned in papermentioned on GitHub report
JunMa11/COVID-19-CT-Seg-Benchmark mentioned on GitHubApache-2.0 report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

3 samples harvested; 0 ran; 0 honoured the contract we drafted; 3 have no recorded run. Read from Syntology's graph 2026-09-24; that is when this build read the record, not when the samples ran.

3unverified

Licence: 0 of the 3 samples are pointer only, meaning Syntology does not serve that copy's text. This page shows no code text for any sample; each one links to its file in the repository.

Harvested from JunMa11/COVID-19-CT-Seg-Benchmark. “Ran” means the sample executed on a synthesized input. It does not mean the output is correct, and nothing here reproduces the paper's results. “Honoured” and “violated” refer to a contract Syntology drafted from the code itself; “our draft was wrong” and “fixture could not drive it” are failures of Syntology's instrument, not of the code.

Each sample ends with its code_sha256, Syntology's identity for that exact code. An agent fetches the stored sample with Syntology's MCP tool get_code(code_sha256="…") (how to connect); click an identity to copy that call.

Repository labels, per sample. official repository: The archive marks this repository official for the paper. named in the paper: The archive records that the paper mentions this repository; it is not marked official. community (archive-listed): In the archive's code links for this paper, not marked official and not recorded as mentioned in the paper. found in paper text by Syntology: Syntology found this repository in the paper's own text; whether it is the authors' implementation is not asserted. community: Not in the archive's code links for this paper; a community repository Syntology harvested. Samples from a repository marked official are listed first. Licence labels name the repository's licence as recorded at harvest. “Pointer only” means Syntology does not serve that copy's text, for one of four reasons: no licence file was found; the licence was not identified; the licence is recorded as permissive but that copy's record is not marked cleared; or the licence is outside the permissive list Syntology serves text under (MIT, Apache-2.0, BSD and similar). Some licences outside that list permit redistribution, such as WTFPL, and GPL-3.0 under its conditions; they are simply not on the list. Hover a licence label for the reason. File links open the file on GitHub at the default branch, which may have changed since the harvest.

compute_average_surface_distance JunMa11/COVID-19-CT-Seg-Benchmark/utils/SurfaceDice.py community (archive-listed) unverified Apache-2.0 (permissive) · f9b271f523aab805 · report
compute_robust_hausdorff JunMa11/COVID-19-CT-Seg-Benchmark/utils/SurfaceDice.py community (archive-listed) unverified Apache-2.0 (permissive) · 28e7a6e0eb50b7a0 · report
compute_surface_distances JunMa11/COVID-19-CT-Seg-Benchmark/utils/SurfaceDice.py community (archive-listed) unverified Apache-2.0 (permissive) · c2cde84212a0d024 · report

Tasks

Domain GeneralizationFew-Shot LearningImage SegmentationManagementMedical Image SegmentationSegmentationSemantic SegmentationTransfer Learning

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections