Papers › Synthetic CT Generation from MRI using 3D Transformer-based Denoising Diffusion Model

Synthetic CT Generation from MRI using 3D Transformer-based Denoising Diffusion Model

31 May 2023arXiv:2305.19467archive 2025-07-28

Shaoyan Pan, Elham Abouei, Jacob Wynne, Tonghe Wang, Richard L. J. Qiu, Yuheng Li, Chih-Wei Chang, Junbo Peng, Justin Roper, Pretesh Patel, David S. Yu, Hui Mao, Xiaofeng Yang

Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning by eliminating the need for CT simulation and error-prone image registration, ultimately reducing patient radiation dose and setup uncertainty. We propose an MRI-to-CT transformer-based denoising diffusion probabilistic model (MC-DDPM) to transform MRI into high-quality sCT to facilitate radiation treatment planning. MC-DDPM implements diffusion processes with a shifted-window transformer network to generate sCT from MRI. The proposed model consists of two processes: a forward process which adds Gaussian noise to real CT scans, and a reverse process in which a shifted-window transformer V-net (Swin-Vnet) denoises the noisy CT scans conditioned on the MRI from the same patient to produce noise-free CT scans. With an optimally trained Swin-Vnet, the reverse diffusion process was used to generate sCT scans matching MRI anatomy. We evaluated the proposed method by generating sCT from MRI on a brain dataset and a prostate dataset. Qualitative evaluation was performed using the mean absolute error (MAE) of Hounsfield unit (HU), peak signal to noise ratio (PSNR), multi-scale Structure Similarity index (MS-SSIM) and normalized cross correlation (NCC) indexes between ground truth CTs and sCTs. MC-DDPM generated brain sCTs with state-of-the-art quantitative results with MAE 43.317 HU, PSNR 27.046 dB, SSIM 0.965, and NCC 0.983. For the prostate dataset, MC-DDPM achieved MAE 59.953 HU, PSNR 26.920 dB, SSIM 0.849, and NCC 0.948. In conclusion, we have developed and validated a novel approach for generating CT images from routine MRIs using a transformer-based DDPM. This model effectively captures the complex relationship between CT and MRI images, allowing for robust and high-quality synthetic CT (sCT) images to be generated in minutes.

PaperPDFCodeCode Syntology ran

In Syntology Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, Syntology's MCP tool lists every function and class Syntology harvested from this paper and whether it ran (how to connect): get_harvested_code_for_paper(arxiv_id="2305.19467")

Code

Syntology Ran 4 of 14 code samples harvested from 1 repository linked to this paper; 10 have no recorded run. Of those that ran: 1 ran · honoured contract; 1 ran · our draft was wrong; 2 ran · fixture could not drive it.

By repository: official repository: 14 samples from 1 repository, 4 ran. The run record, sample by sample. “Ran” means executed on a synthesized input, not that the code is correct or reproduces the paper.

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

14 samples harvested; 4 ran; 1 honoured the contract we drafted; 10 have no recorded run. Read from Syntology's graph 2026-09-24; that is when this build read the record, not when the samples ran.

1ran · honoured contract
1ran · our draft was wrong
2ran · fixture could not drive it
10unverified

Licence: 0 of the 14 samples are pointer only, meaning Syntology does not serve that copy's text. This page shows no code text for any sample; each one links to its file in the repository.

Harvested from shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model. “Ran” means the sample executed on a synthesized input. It does not mean the output is correct, and nothing here reproduces the paper's results. “Honoured” and “violated” refer to a contract Syntology drafted from the code itself; “our draft was wrong” and “fixture could not drive it” are failures of Syntology's instrument, not of the code.

Each sample ends with its code_sha256, Syntology's identity for that exact code. An agent fetches the stored sample with Syntology's MCP tool get_code(code_sha256="…") (how to connect); click an identity to copy that call.

Repository labels, per sample. official repository: The archive marks this repository official for the paper. named in the paper: The archive records that the paper mentions this repository; it is not marked official. community (archive-listed): In the archive's code links for this paper, not marked official and not recorded as mentioned in the paper. found in paper text by Syntology: Syntology found this repository in the paper's own text; whether it is the authors' implementation is not asserted. community: Not in the archive's code links for this paper; a community repository Syntology harvested. Samples from a repository marked official are listed first. Licence labels name the repository's licence as recorded at harvest. “Pointer only” means Syntology does not serve that copy's text, for one of four reasons: no licence file was found; the licence was not identified; the licence is recorded as permissive but that copy's record is not marked cleared; or the licence is outside the permissive list Syntology serves text under (MIT, Apache-2.0, BSD and similar). Some licences outside that list permit redistribution, such as WTFPL, and GPL-3.0 under its conditions; they are simply not on the list. Hover a licence label for the reason. File links open the file on GitHub at the default branch, which may have changed since the harvest.

get_window_size shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/SwinUnetr.py official repository ran · fixture could not drive it MIT (permissive) · 34484ba7deb03520 · report
normal_kl shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/diffusion/GaussianDiffusion.py official repository ran · honoured contract fingerprinted MIT (permissive) · 8afbfc42c6ea0448 · report
space_timesteps shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/diffusion/respace.py official repository ran · fixture could not drive it MIT (permissive) · ea9dbc131adf582e · report
zero_module shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/util_network.py official repository ran · our draft was wrong MIT (permissive) · 129b804760b3115f · report
approx_standard_normal_cdf shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/diffusion/GaussianDiffusion.py official repository unverified MIT (permissive) · 9e86a9b74c867cbf · report
avg_pool_nd shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/util_network.py official repository unverified MIT (permissive) · ecd0fc28815b65ae · report
create_named_schedule_sampler shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/diffusion/resampler.py official repository unverified MIT (permissive) · 03a8783b9f571ada · report
discretized_gaussian_log_likelihood shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/diffusion/GaussianDiffusion.py official repository unverified MIT (permissive) · 3daaa122f404d7d1 · report
window_partition shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/SwinUnetr.py official repository unverified MIT (permissive) · 8cd5fa7e1d693a92 · report
window_partition shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/nnFormer.py official repository unverified MIT (permissive) · 17c1c7e517679162 · report
window_reverse shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/SwinUnetr.py official repository unverified MIT (permissive) · 1545b891ff0bbdd7 · report
window_reverse shaoyanpan/Synthetic-CT-generation-from-MRI-using-3D-transformer-based-denoising-diffusion-model/network/nnFormer.py official repository unverified MIT (permissive) · 99f891ae38f89e1f · report

Tasks

AnatomyDenoisingImage RegistrationMS-SSIMSSIM

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Methods

DiffusionMAE

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections