SPARC4 control system
Denis Bernardes, Orlando Verducci Junior, Francisco Rodrigues, Claudia Vilega Rodrigues, Luciano Fraga, Eder Martioli, Clemens D. Gneiding, André Luiz de Moura Alves, Juliano Romão, Laerte Andrade, Leandro de Almeida, Ana Carolina Mattiuci, Flavio Felipe Ribeiro, Wagner Schlindwein, Jesulino Bispo dos Santos, Francisco Jose Jablonski, Julio Cesar Neves Campagnolo, Rene Laporte
The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.
SPARC4 is a new astronomical instrument developed entirely by Brazilian institutions, currently installed on the 1.6-m Perkin-Elmer telescope of the Pico dos Dias Observatory. It allows the user to perform photometric or polarimetric observations simultaneously in the four SDSS bands (g, r, i, and z). In this paper, we describe the control system developed for SPARC4. This system is composed of S4ACS, S4ICS, and S4GUI softwares and associated hardware. S4ACS is responsible for controlling the four EMCCD scientific cameras (one for each instrument band). S4ICS controls the sensors and motors responsible for the moving parts of SPARC4. Finally, S4GUI is the interface used to perform observations, which includes the choice of instrument configuration and image acquisition parameters. S4GUI communicates with the instrument subsystems and with some observatory facilities, needed during the observations. Bench tests were performed for the determination of the overheads added by SPARC4 control system in the acquisition of photometric and polarimetric series of images. In the photometric mode, SPARC4 allows the acquisition of a series of 1400 full-frame images, with a deadtime of 4.5 ms between images. Besides, several image series can be concatenated with a deadtime of 450 ms plus the readout time of the last image. For the polarimetric mode, measurements can be obtained with a deadtime of 1.41 s plus the image readout time between subsequent waveplate positions. For both photometric and polarimetric modes, the user can choose among operating modes with image readout times between 5.9 ms and 1.24 s, which ultimately defines the instrument temporal performance.
Code
Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.
Code Syntology ran Syntology
Not run by Syntology. Nothing on this page verifies that the listed code works.
Results from the paper archive 2025-07-28
No leaderboard rows for this paper in the archive.
Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections