Papers › Self-supervision for medical image classification: state-of-the-art performance with...

Self-supervision for medical image classification: state-of-the-art performance with ~100 labeled training samples per class

11 Apr 2023arXiv:2304.05163archive 2025-07-28

Maximilian Nielsen, Laura Wenderoth, Thilo Sentker, René Werner

Is self-supervised deep learning (DL) for medical image analysis already a serious alternative to the de facto standard of end-to-end trained supervised DL? We tackle this question for medical image classification, with a particular focus on one of the currently most limiting factors of the field: the (non-)availability of labeled data. Based on three common medical imaging modalities (bone marrow microscopy, gastrointestinal endoscopy, dermoscopy) and publicly available data sets, we analyze the performance of self-supervised DL within the self-distillation with no labels (DINO) framework. After learning an image representation without use of image labels, conventional machine learning classifiers are applied. The classifiers are fit using a systematically varied number of labeled data (1-1000 samples per class). Exploiting the learned image representation, we achieve state-of-the-art classification performance for all three imaging modalities and data sets with only a fraction of between 1% and 10% of the available labeled data and about 100 labeled samples per class.

PaperPDFCode

Syntology This paper's arXiv id is not in Syntology's Atlas id list (549,449 ids, as this build read them; the read time is in the build record), so this page links to no Syntology page for it. The list is not the whole graph; Syntology's feed shows papers as they enter the graph.

Code

ipmi-icns-uke/sparsam officialmentioned in papermentioned on GitHubpytorchMITSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to Emerging Properties in Self-Supervised Vision Transformers (arXiv:2104.14294; that paper's own run record: 14 ran (of which 0 constructed an object rather than computing a result; 10 with no instrument failure: 0 honoured, 1 violated, 9 with no contract checked; 4 where Syntology's instrument failed) · 6 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Image ClassificationMedical Image AnalysisMedical Image Classificationimage-classification

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections