Papers › Ring Artifact Correction in Photon-Counting Spectral CT Using a Convolutional Neural...

Ring Artifact Correction in Photon-Counting Spectral CT Using a Convolutional Neural Network With Spectral Loss

2 Feb 2023arXiv:2302.00921links table onlyarchive 2025-07-28

Dennis Hein, Konstantinos Liappis, Fredrik Grönberg, Alma Eguizabal, Mats Persson

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design consideration is to build detector elements that are sufficiently homogeneous. In practice, there will always be a degree of inhomogeneity in the detector elements, which will materialize as variations in the energy bin thresholds. Without proper detector calibration, this will lead to streak artifacts in the sinograms and corresponding ring artifacts in the reconstructed images, which limit their clinical usefulness. Since detector calibration is a time-consuming process, having access to a fast ring correction technique may greatly improve workflow. In this paper, we propose a deep learning-based post-processing technique for ring artifact correction in photon-counting spectral CT. We train a UNet with a custom loss to correct for ring artifacts in the material basis images. Our proposed loss is made ``task-aware'' by explicitly incorporating the fact that we are working with spectral CT by combining a L1-loss operating on the material basis images with a perceptual loss, using VGG16 as feature extractor, operating on 70 keV virtual monoenergetic images. Our results indicate that using this novel loss greatly improves performance. We demonstrate that our proposed method can successfully produce ring corrected 40, 70, and 100 keV virtual monoenergetic images.

PaperPDFCode

Code

kth-physics-of-medical-imaging/deep_spectral_ring officialmentioned in papermentioned on GitHubpytorch report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections