Papers › Reproducibility of an airway tapering measurement in CT with application to bronchiectasis

Reproducibility of an airway tapering measurement in CT with application to bronchiectasis

16 Sep 2019arXiv:1909.07454archive 2025-07-28

Kin Quan, Ryutaro Tanno, Rebecca J. Shipley, Jeremy S. Brown, Joseph Jacob, John R. Hurst, David J. Hawkes

Purpose: This paper proposes a pipeline to acquire a scalar tapering measurement from the carina to the most distal point of an individual airway visible on CT. We show the applicability of using tapering measurements on clinically acquired data by quantifying the reproducibility of the tapering measure. Methods: We generate a spline from the centreline of an airway to measure the area and arclength at contiguous intervals. The tapering measurement is the gradient of the linear regression between area in log space and arclength. The reproducibility of the measure was assessed by analysing different radiation doses, voxel sizes and reconstruction kernel on single timepoint and longitudinal CT scans and by evaluating the effct of airway bifurcations. Results: Using 74 airways from 10 CT scans, we show a statistical difference, p = 3.4 × 10⁻⁴ in tapering between healthy airways (n = 35) and those affected by bronchiectasis (n = 39). The difference between the mean of the two populations was 0.011mm⁻¹ and the difference between the medians of the two populations was 0.006mm⁻¹. The tapering measurement retained a 95\% confidence interval of ±0.005mm⁻¹ in a simulated 25 mAs scan and retained a 95% confidence of ±0.005mm⁻¹ on simulated CTs up to 1.5 times the original voxel size. Conclusion: We have established an estimate of the precision of the tapering measurement and estimated the effect on precision of simulated voxel size and CT scan dose. We recommend that the scanner calibration be undertaken with the phantoms as described, on the specific CT scanner, radiation dose and reconstruction algorithm that is to be used in any quantitative studies. Our code is available at https://github.com/quan14/AirwayTaperingInCT

PaperPDFCode

Code

quan14/AirwayTaperingInCT officialmentioned in paper report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Methods

Linear Regression

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections