Papers › Particle detection performance and Geant4 simulation with low-cost CMOS technology

Particle detection performance and Geant4 simulation with low-cost CMOS technology

21 Feb 2024arXiv:2402.13993links table onlyarchive 2025-07-28

M. Bonnett Del Alamo, R. Helaconde, C. Soncco, J. Bazo, A. M. Gago

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

We evaluate the performance of an Omnivision OV5647 CMOS image sensor (5 Mp) for detecting radiation from Sr90 and Cs137 sources. Our experimental setup uses a Raspberry Pi 3 mini-computer for data acquisition, with image processing using Python and OpenCV libraries. We specify the necessary settings to convert a standard camera into a particle detector sensitive to electrons and photons, including a two-step background filtering procedure. In addition, we implement the first detailed Geant4 simulation that describes the layered geometry and material composition of a commercial CMOS sensor along with the radioactive sources. To enhance the simulation, we include an algorithm for charge diffusion and conversion of the energy deposited by electrons and photons into ADC counts. Our measurements are presented in terms of cluster size, the maximum ADC signal per cluster, and the number of clusters as a function of distance. We find a good agreement between the experimental data and simulation for all these observables, and we can reproduce the correlation between cluster size and maximum ADC signal per cluster. Thus, this simulation, cross-checked with data, can be used to test the feasibility of further particle detection ideas without the need to implement an experimental setup. However, the sensor has limited primary energy resolution and is thus unable to distinguish between different radioactive sources. Nevertheless, given the accurate measurement of energy deposition, the sensor, once calibrated, is suitable for dosimetric measurements of source activities.

PaperPDFCode

Code

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections