Papers › Optimizing the Traversal Time for Gantry Trajectories for Proton Arc Therapy Treatment Plans

Optimizing the Traversal Time for Gantry Trajectories for Proton Arc Therapy Treatment Plans

19 Oct 2023arXiv:2310.12731links table onlyarchive 2025-07-28

Viktor Wase, Otte Marthin, Albin Fredriksson, Anton Finnson

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

Background: Proton arc therapy is an emerging radiation therapy technique where either the gantry or the patient continuously rotates during the irradiation treatment. One of the perceived advantages of proton arc therapy is the reduced treatment time, but it is still unclear exactly how long these treatment times will be, given that no machine capable of its delivery is available at the market at the time of writing. Purpose: We introduce the algorithm Arc Trajectory Optimization Method (ATOM), which aims to determine an efficient velocity profile for the gantry for rapid delivery of a given proton arc treatment plan. Methods: ATOM computes the trajectory with the shortest delivery time while ensuring there is enough time to deliver all spots in each energy layer and switch energy between layers. The feasibility of the dynamic gantry movement was assured by enforcing maximum and minimum limits for velocity, acceleration, and jerk. This was achieved by discretizing the gantry velocity and combining the A* algorithm with the open-source motion generation library Ruckig. The algorithm was tested on a synthetic data set as well as a liver case, a prostate case and a head and neck case. Results: Arc trajectories for plans with 360 energy layers were calculated in under a second using 256 discrete velocities. Conclusions: ATOM is an open-source C++ library with a Python interface that rapidly generates velocity profiles, making it a highly efficient tool for determining proton arc delivery times, which could be integrated into the treatment planning process.

PaperPDFCode

Code

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections