Papers › On learning adaptive acquisition policies for undersampled multi-coil MRI reconstruction

On learning adaptive acquisition policies for undersampled multi-coil MRI reconstruction

30 Mar 2022arXiv:2203.16392archive 2025-07-28

Tim Bakker, Matthew Muckley, Adriana Romero-Soriano, Michal Drozdzal, Luis Pineda

Most current approaches to undersampled multi-coil MRI reconstruction focus on learning the reconstruction model for a fixed, equidistant acquisition trajectory. In this paper, we study the problem of joint learning of the reconstruction model together with acquisition policies. To this end, we extend the End-to-End Variational Network with learnable acquisition policies that can adapt to different data points. We validate our model on a coil-compressed version of the large scale undersampled multi-coil fastMRI dataset using two undersampling factors: 4× and 8×. Our experiments show on-par performance with the learnable non-adaptive and handcrafted equidistant strategies at 4×, and an observed improvement of more than 2% in SSIM at 8× acceleration, suggesting that potentially-adaptive k-space acquisition trajectories can improve reconstructed image quality for larger acceleration factors. However, and perhaps surprisingly, our best performing policies learn to be explicitly non-adaptive.

PaperPDFCode

Syntology This paper's arXiv id is not in Syntology's Atlas id list (549,449 ids, as this build read them; the read time is in the build record), so this page links to no Syntology page for it. The list is not the whole graph; Syntology's feed shows papers as they enter the graph.

Code

facebookresearch/fastMRI officialmentioned in papermentioned on GitHubpytorchSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to fastMRI: An Open Dataset and Benchmarks for Accelerated MRI (arXiv:1811.08839; that paper's own run record: 5 ran (of which 0 constructed an object rather than computing a result; 3 with no instrument failure: 0 honoured, 0 violated, 3 with no contract checked; 2 where Syntology's instrument failed) · 0 unverified) and End-to-End Variational Networks for Accelerated MRI Reconstruction (arXiv:2004.06688; that paper's own run record: 3 ran (of which 0 constructed an object rather than computing a result; 2 with no instrument failure: 0 honoured, 0 violated, 2 with no contract checked; 1 where Syntology's instrument failed) · 2 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

MRI ReconstructionSSIM

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections