Papers › Occupant-Oriented Demand Response with Multi-Zone Thermal Building Control
Occupant-Oriented Demand Response with Multi-Zone Thermal Building Control
Moritz Frahm, Thomas Dengiz, Philipp Zwickel, Heiko Maaß, Jörg Matthes, Veit Hagenmeyer
In future energy systems with high shares of renewable energy sources, the electricity demand of buildings has to react to the fluctuating electricity generation in view of stability. As buildings consume one-third of global energy and almost half of this energy accounts for Heating, Ventilation, and Air Conditioning (HVAC) systems, HVAC are suitable for shifting their electricity consumption in time. To this end, intelligent control strategies are necessary as the conventional control of HVAC is not optimized for the actual demand of occupants and the current situation in the electricity grid. In this paper, we present the novel multi-zone controller Price Storage Control (PSC) that not only considers room-individual Occupants' Thermal Satisfaction (OTS), but also the available energy storage, and energy prices. The main feature of PSC is that it does not need a building model or forecasts of future demands to derive the control actions for multiple rooms in a building. For comparison, we use an ideal, error-free Model Predictive Control (MPC), a simplified variant without storage consideration (PC), and a conventional hysteresis-based two-point control. We evaluate the four controllers in a multi-zone environment for heating a building in winter and consider two different scenarios that differ in how much the permitted temperatures vary. In addition, we compare the impact of model parameters with high and low thermal capacitance. The results show that PSC strongly outperforms the conventional control approach in both scenarios and for both parameters. For high capacitance, it leads to 22 % costs reduction while the ideal MPC achieves cost reductions of more than 39 %. Considering that PSC does not need any building model or forecast, as opposed to MPC, the results support the suitability of our developed control strategy for controlling HVAC systems in future energy systems.
Code
Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.
Code Syntology ran Syntology
Not run by Syntology. Nothing on this page verifies that the listed code works.
Tasks
Results from the paper archive 2025-07-28
No leaderboard rows for this paper in the archive.
Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections