Papers › Near out-of-distribution detection for low-resolution radar micro-Doppler signatures

Near out-of-distribution detection for low-resolution radar micro-Doppler signatures

12 May 2022arXiv:2205.07869archive 2025-07-28

Martin Bauw, Santiago Velasco-Forero, Jesus Angulo, Claude Adnet, Olivier Airiau

Near out-of-distribution detection (OODD) aims at discriminating semantically similar data points without the supervision required for classification. This paper puts forward an OODD use case for radar targets detection extensible to other kinds of sensors and detection scenarios. We emphasize the relevance of OODD and its specific supervision requirements for the detection of a multimodal, diverse targets class among other similar radar targets and clutter in real-life critical systems. We propose a comparison of deep and non-deep OODD methods on simulated low-resolution pulse radar micro-Doppler signatures, considering both a spectral and a covariance matrix input representation. The covariance representation aims at estimating whether dedicated second-order processing is appropriate to discriminate signatures. The potential contributions of labeled anomalies in training, self-supervised learning, contrastive learning insights and innovative training losses are discussed, and the impact of training set contamination caused by mislabelling is investigated.

PaperPDFCode

Syntology This paper's arXiv id is not in Syntology's Atlas id list (549,449 ids, as this build read them; the read time is in the build record), so this page links to no Syntology page for it. The list is not the whole graph; Syntology's feed shows papers as they enter the graph.

Code

blupblupblup/doppler-signatures-generation officialmentioned in papermentioned on GitHubSyntology: not harvested report
blupblupblup/near-ood-doppler-signatures officialmentioned in papermentioned on GitHubpytorchMITSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to MedMNIST Classification Decathlon: A Lightweight AutoML Benchmark for Medical Image Analysis (arXiv:2010.14925; that paper's own run record: 6 ran (of which 0 constructed an object rather than computing a result; 4 with no instrument failure: 0 honoured, 0 violated, 4 with no contract checked; 2 where Syntology's instrument failed) · 4 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Contrastive LearningGeometry-aware processingOne-class classifierOut-of-Distribution DetectionSecond-order methodsSelf-Supervised Learning

Datasets

Introduced by this paper, per the archive.

Simulated micro-Doppler Signatures

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Methods

Contrastive Learning

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections