Papers › MR sequence design to account for non-ideal gradient performance

MR sequence design to account for non-ideal gradient performance

26 Mar 2024arXiv:2403.17575links table onlyarchive 2025-07-28

Daniel J West, Felix Glang, Jonathan Endres, David Leitão, Moritz Zaiss, Joseph V Hajnal, Shaihan J Malik

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

MRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy currents produced by gradient fields; usually these are compensated by pre-emphasizing demanded waveforms. This process typically happens invisibly to the pulse sequence designer, allowing them to assume achieved gradient waveforms will be as desired. Whilst convenient, this requires system specifications exposed to the end-user to be substantially down-rated, since pre-emphasis adds an extra overhead to the waveforms. This strategy is undesirable for lower performance or resource-limited hardware. Instead, we propose an optimization-based method to design pre-compensated gradient waveforms that: (i) explicitly respect hardware constraints and (ii) improve imaging performance by correcting k-space samples directly. Gradient waveforms are numerically optimized by including a model for system imperfections. This is investigated in simulation using an exponential eddy current model, then experimentally using an empirical gradient system transfer function on a 7T MRI system. Our proposed method discovers solutions that produce negligible reconstruction errors while satisfying gradient system limits, even when classic pre-emphasis produces infeasible results. Substantial reduction in ghosting artefacts from EPI imaging was observed, including an average reduction of 77% in ghost amplitude in phantoms. This work demonstrates numerical optimization of gradient waveforms, yielding substantially improved image quality when given a model for system imperfections. While the method as implemented has limited flexibility, it could enable more efficient hardware usage, and may prove particularly important for maximizing performance of lower-cost systems.

PaperPDFCode

Code

mriphysics/digital_twin_optimisation officialmentioned in papermentioned on GitHubpytorch report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections