Papers › Method for Measuring Absolute Optical Properties of Turbid Samples in a Standard Cuvette

Method for Measuring Absolute Optical Properties of Turbid Samples in a Standard Cuvette

14 Sep 2022arXiv:2209.06919links table onlyarchive 2025-07-28

Giles Blaney, Angelo Sassaroli, Sergio Fantini

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

Many applications seek to measure a sample's absorption coefficient spectrum to retrieve the chemical makeup. Many real world samples are optically turbid, causing scattering confounds which many commercial spectrometers cannot address. Using diffusion theory and considering absorption and reduced scattering coefficients on the order of 0.01 per mm and 1 per mm, respectively, we develop a method which utilizes frequency-domain to measure absolute optical properties of turbid samples in a standard cuvette (45 mm by 10 mm by 10 mm). Inspired by the self calibrating method, which removes instrumental confounds, the method uses measurements of the diffuse complex transmittance at two sets of two different source-detector distances. We find: this works best for highly scattering samples (reduced scattering coefficient above 1 per mm); higher relative error in the absorption coefficient compared to the reduced scattering coefficient; accuracy is tied to knowledge of the samples index of refraction. Noise simulations with 0.1 percent amplitude and 0.1 deg (1.7 mrad) phase uncertainty find errors in absorption and reduced scattering coefficients of 4 percent and 1 percent, respectively. We expect that higher error in the absorption coefficient can be alleviated with highly scattering samples and that boundary condition confounds may be suppressed by designing a cuvette with high index of refraction. Further work will investigate implementation and reproducibility.

PaperPDFCode

Code

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections