Papers › Method for Estimation of Nonlinear λ-I Relation of Single Phase Power Transformer Core...

Method for Estimation of Nonlinear λ-I Relation of Single Phase Power Transformer Core by Using On-line Measurable Parameters

28 Apr 2020arXiv:2004.13583archive 2025-07-28

In design of new power transformers, reliable and efficient tools are required to expedite research and development processes. Some of these tools are used to interpret the data obtained from the transformer tests for better judgement about the response of the transformer. In this paper a clear procedure is proposed to estimate the nonlinear relation between flux and excitation current of power transformers by using online measurable data, which is the main reason of the input current harmonics. It is shown that the procedure computes this relation with very high precision and leads to identical results to that applied in simulation.

PaperPDFCode

Code

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections