Papers › MedDeblur: Medical Image Deblurring with Residual Dense Spatial-Asymmetric Attention
MedDeblur: Medical Image Deblurring with Residual Dense Spatial-Asymmetric Attention
S. M. A. Sharif, Rizwan Ali Naqvi, Zahid Mehmood, Jamil Hussain, Ahsan Ali, Seung-Won Lee
Medical image acquisition devices are susceptible to producing blurry images due to respiratory and patient movement. Despite having a notable impact on such blind-motion deblurring, medical image deblurring is still underexposed. This study proposes an end-to-end scale-recurrent deep network to learn the deblurring from multi-modal medical images. The proposed network comprises a novel residual dense block with spatial-asymmetric attention to recover salient information while learning medical image deblurring. The performance of the proposed methods has been densely evaluated and compared with the existing deblurring methods. The experimental results demonstrate that the proposed method can remove blur from medical images without illustrating visually disturbing artifacts. Furthermore, it outperforms the deep deblurring methods in qualitative and quantitative evaluation by a noticeable margin. The applicability of the proposed method has also been verified by incorporating it into various medical image analysis tasks such as segmentation and detection. The proposed deblurring method helps accelerate the performance of such medical image analysis tasks by removing blur from blurry medical inputs.
Code
Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.
Code Syntology ran Syntology
Not run by Syntology. Nothing on this page verifies that the listed code works.
Tasks
Results from the paper archive 2025-07-28
| Task | Dataset | Model | Metric | Value | Rank at snapshot | Leaderboard | Report |
|---|---|---|---|---|---|---|---|
| Medical Image Deblurring | Brain MRI segmentation | MedDeblur | Average PSNR | 32.05 | #1 of 1 | Archive leaderboard | report |
| Medical Image Deblurring | COVID-19 CT Scan | MedDeblur | Average PSNR | 28.74 | #1 of 1 | Archive leaderboard | report |
| Medical Image Deblurring | ChexPert | MedDeblur | Average PSNR | 28.09 | #1 of 1 | Archive leaderboard | report |
| Medical Image Deblurring | Human Protein Atlas Image | MedDeblur | Average PSNR | 31.13 | #1 of 1 | Archive leaderboard | report |
Ranks are positions in the archive's leaderboards as they stood at the 2025-07-28 snapshot. Results published since then are not among these rows, so a rank here is not a current standing.