Papers › Machine-Learning-Based Diagnostics of EEG Pathology

Machine-Learning-Based Diagnostics of EEG Pathology

11 Feb 2020arXiv:2002.05115archive 2025-07-28

Lukas Alexander Wilhelm Gemein, Robin Tibor Schirrmeister, Patryk Chrabąszcz, Daniel Wilson, Joschka Boedecker, Andreas Schulze-Bonhage, Frank Hutter, Tonio Ball

Machine learning (ML) methods have the potential to automate clinical EEG analysis. They can be categorized into feature-based (with handcrafted features), and end-to-end approaches (with learned features). Previous studies on EEG pathology decoding have typically analyzed a limited number of features, decoders, or both. For a I) more elaborate feature-based EEG analysis, and II) in-depth comparisons of both approaches, here we first develop a comprehensive feature-based framework, and then compare this framework to state-of-the-art end-to-end methods. To this aim, we apply the proposed feature-based framework and deep neural networks including an EEG-optimized temporal convolutional network (TCN) to the task of pathological versus non-pathological EEG classification. For a robust comparison, we chose the Temple University Hospital (TUH) Abnormal EEG Corpus (v2.0.0), which contains approximately 3000 EEG recordings. The results demonstrate that the proposed feature-based decoding framework can achieve accuracies on the same level as state-of-the-art deep neural networks. We find accuracies across both approaches in an astonishingly narrow range from 81--86\%. Moreover, visualizations and analyses indicated that both approaches used similar aspects of the data, e.g., delta and theta band power at temporal electrode locations. We argue that the accuracies of current binary EEG pathology decoders could saturate near 90\% due to the imperfect inter-rater agreement of the clinical labels, and that such decoders are already clinically useful, such as in areas where clinical EEG experts are rare. We make the proposed feature-based framework available open source and thus offer a new tool for EEG machine learning research.

PaperPDFCodeCode Syntology ran

In Syntology Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, Syntology's MCP tool lists every function and class Syntology harvested from this paper and whether it ran (how to connect): get_harvested_code_for_paper(arxiv_id="2002.05115")

Code

Syntology Ran 1 of 1 code samples harvested from 1 repository linked to this paper; 0 have no recorded run. Of those that ran: 1 ran · fixture could not drive it.

By repository: official repository: 1 sample from 1 repository, 1 ran. The run record, sample by sample. “Ran” means executed on a synthesized input, not that the code is correct or reproduces the paper.

gemeinl/auto-eeg-diagnosis-comparison officialmentioned in paperpytorch report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

1 sample harvested; 1 ran; 0 honoured the contract we drafted; 0 have no recorded run. Read from Syntology's graph 2026-09-24; that is when this build read the record, not when the samples ran.

1ran · fixture could not drive it

Licence: 1 of the 1 sample is pointer only, meaning Syntology does not serve that copy's text. This page shows no code text for any sample; each one links to its file in the repository.

Harvested from gemeinl/auto-eeg-diagnosis-comparison. “Ran” means the sample executed on a synthesized input. It does not mean the output is correct, and nothing here reproduces the paper's results. “Honoured” and “violated” refer to a contract Syntology drafted from the code itself; “our draft was wrong” and “fixture could not drive it” are failures of Syntology's instrument, not of the code.

Each sample ends with its code_sha256, Syntology's identity for that exact code. An agent fetches the stored sample with Syntology's MCP tool get_code(code_sha256="…") (how to connect); click an identity to copy that call.

Repository labels, per sample. official repository: The archive marks this repository official for the paper. named in the paper: The archive records that the paper mentions this repository; it is not marked official. community (archive-listed): In the archive's code links for this paper, not marked official and not recorded as mentioned in the paper. found in paper text by Syntology: Syntology found this repository in the paper's own text; whether it is the authors' implementation is not asserted. community: Not in the archive's code links for this paper; a community repository Syntology harvested. Samples from a repository marked official are listed first. Licence labels name the repository's licence as recorded at harvest. “Pointer only” means Syntology does not serve that copy's text, for one of four reasons: no licence file was found; the licence was not identified; the licence is recorded as permissive but that copy's record is not marked cleared; or the licence is outside the permissive list Syntology serves text under (MIT, Apache-2.0, BSD and similar). Some licences outside that list permit redistribution, such as WTFPL, and GPL-3.0 under its conditions; they are simply not on the list. Hover a licence label for the reason. File links open the file on GitHub at the default branch, which may have changed since the harvest.

nll_loss_on_mean gemeinl/auto-eeg-diagnosis-comparison/code/tuh_auto_diag.py official repository ran · fixture could not drive it no licence file found · pointer only · 535d2e55e67ae2be · report

Tasks

BIG-bench Machine LearningEEGElectroencephalogram (EEG)

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections