Papers › Improving the Factual Correctness of Radiology Report Generation with Semantic Rewards

Improving the Factual Correctness of Radiology Report Generation with Semantic Rewards

21 Oct 2022arXiv:2210.12186archive 2025-07-28

Jean-Benoit Delbrouck, Pierre Chambon, Christian Bluethgen, Emily Tsai, Omar Almusa, Curtis P. Langlotz

Neural image-to-text radiology report generation systems offer the potential to improve radiology reporting by reducing the repetitive process of report drafting and identifying possible medical errors. These systems have achieved promising performance as measured by widely used NLG metrics such as BLEU and CIDEr. However, the current systems face important limitations. First, they present an increased complexity in architecture that offers only marginal improvements on NLG metrics. Secondly, these systems that achieve high performance on these metrics are not always factually complete or consistent due to both inadequate training and evaluation. Recent studies have shown the systems can be substantially improved by using new methods encouraging 1) the generation of domain entities consistent with the reference and 2) describing these entities in inferentially consistent ways. So far, these methods rely on weakly-supervised approaches (rule-based) and named entity recognition systems that are not specific to the chest X-ray domain. To overcome this limitation, we propose a new method, the RadGraph reward, to further improve the factual completeness and correctness of generated radiology reports. More precisely, we leverage the RadGraph dataset containing annotated chest X-ray reports with entities and relations between entities. On two open radiology report datasets, our system substantially improves the scores up to 14.2% and 25.3% on metrics evaluating the factual correctness and completeness of reports.

PaperPDFCode

In Syntology View this paper on Syntology, its page in Syntology's graph. That page lists the repositories linked to the paper, the abstract and the calls for agents.

Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, on Syntology's MCP service (how to connect):

Code

jbdel/vilmedic officialmentioned in paperpytorchSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to Generating Radiology Reports via Memory-driven Transformer (arXiv:2010.16056; that paper's own run record: 26 ran (of which 13 constructed an object rather than computing a result; 20 with no instrument failure: 3 honoured, 3 violated, 14 with no contract checked; 6 where Syntology's instrument failed) · 5 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Image to textNamed Entity RecognitionNamed Entity Recognition (NER)named-entity-recognition

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections