Papers › ICON: Improving Inter-Report Consistency in Radiology Report Generation via...

ICON: Improving Inter-Report Consistency in Radiology Report Generation via Lesion-aware Mixup Augmentation

20 Feb 2024arXiv:2402.12844archive 2025-07-28

Wenjun Hou, Yi Cheng, Kaishuai Xu, Yan Hu, Wenjie Li, Jiang Liu

Previous research on radiology report generation has made significant progress in terms of increasing the clinical accuracy of generated reports. In this paper, we emphasize another crucial quality that it should possess, i.e., inter-report consistency, which refers to the capability of generating consistent reports for semantically equivalent radiographs. This quality is even of greater significance than the overall report accuracy in terms of ensuring the system's credibility, as a system prone to providing conflicting results would severely erode users' trust. Regrettably, existing approaches struggle to maintain inter-report consistency, exhibiting biases towards common patterns and susceptibility to lesion variants. To address this issue, we propose ICON, which improves the inter-report consistency of radiology report generation. Aiming to enhance the system's ability to capture similarities in semantically equivalent lesions, our approach first involves extracting lesions from input images and examining their characteristics. Then, we introduce a lesion-aware mixup technique to ensure that the representations of the semantically equivalent lesions align with the same attributes, achieved through a linear combination during the training phase. Extensive experiments on three publicly available chest X-ray datasets verify the effectiveness of our approach, both in terms of improving the consistency and accuracy of the generated reports.

PaperPDFCode

In Syntology View this paper on Syntology, its page in Syntology's graph. That page lists the repositories linked to the paper, the abstract and the calls for agents.

Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, on Syntology's MCP service (how to connect):

Code

wjhou/icon officialmentioned in papermentioned on GitHubpytorchApache-2.0Syntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to CheXbert: Combining Automatic Labelers and Expert Annotations for Accurate Radiology... (arXiv:2004.09167; that paper's own run record: 15 ran (of which 0 constructed an object rather than computing a result; 10 with no instrument failure: 0 honoured, 0 violated, 10 with no contract checked; 5 where Syntology's instrument failed) · 2 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Medical Report Generation

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Methods

ALIGNMixup

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections