Papers › High Cadence Optical Transient Searches using Drift Scan Imaging III: Development of...

High Cadence Optical Transient Searches using Drift Scan Imaging III: Development of an Inexpensive Drive Control System and Characterisation and Correction of Drive System Periodic Errors

17 Jun 2021arXiv:2106.09406links table onlyarchive 2025-07-28

S. J. Tingay

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

In order to further develop and implement novel drift scan imaging experiments to undertake wide field, high time resolution surveys for millisecond optical transients, an appropriate telescope drive system is required. This paper describes the development of a simple and inexpensive hardware and software system to monitor, characterise, and correct the primary category of telescope drive errors, periodic errors due to imperfections in the drive and gear chain. A model for the periodic errors is generated from direct measurements of the telescope drive shaft rotation, verified by comparison to astronomical measurements of the periodic errors. The predictive model is generated and applied in real-time in the form of corrections to the drive rate. A demonstration of the system shows that that inherent periodic errors of peak-to-peak amplitude ~100'' are reduced to below the seeing limit of ~3''. This demonstration allowed an estimate of the uncertainties on the transient sensitivity timescales of the prototype survey of Tingay & Joubert (2021), with the nominal timescale sensitivity of 21 ms revised to be in the range of 20 - 22 ms, which does not significantly affect the results of the experiment. The correction system will be adopted into the final version of high cadence imaging experiment, which is currently under construction. The correction system is inexpensive (<$A100) and composed of readily available hardware, and is readily adaptable to other applications. Design details and codes are therefore made publicly available.

PaperPDFCode

Code

steven-tingay/High-Cadence-Imaging-III officialmentioned in paper report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections