Papers › CardioLab: Laboratory Values Estimation from Electrocardiogram Features -- An Exploratory Study

CardioLab: Laboratory Values Estimation from Electrocardiogram Features -- An Exploratory Study

26 Jul 2024arXiv:2407.18629archive 2025-07-28

Juan Miguel Lopez Alcaraz, Nils Strodthoff

Introduction: Laboratory value represents a cornerstone of medical diagnostics, but suffers from slow turnaround times, and high costs and only provides information about a single point in time. The continuous estimation of laboratory values from non-invasive data such as electrocardiogram (ECG) would therefore mark a significant frontier in healthcare monitoring. Despite its transformative potential, this domain remains relatively underexplored within the medical community. Methods: In this preliminary study, we used a publicly available dataset (MIMIC-IV-ECG) to investigate the feasibility of inferring laboratory values from ECG features and patient demographics using tree-based models (XGBoost). We define the prediction task as a binary prediction problem of predicting whether the lab value falls into low or high abnormalities. The model performance can then be assessed using AUROC. Results: Our findings demonstrate promising results in the estimation of laboratory values related to different organ systems based on a small yet comprehensive set of features. While further research and validation are warranted to fully assess the clinical utility and generalizability of ECG-based estimation in healthcare monitoring, our findings lay the groundwork for future investigations into approaches to laboratory value estimation using ECG data. Such advancements hold promise for revolutionizing predictive healthcare applications, offering faster, non-invasive, and more affordable means of patient monitoring.

PaperPDFCode

Syntology This paper's arXiv id is not in Syntology's Atlas id list (549,449 ids, as this build read them; the read time is in the build record), so this page links to no Syntology page for it. The list is not the whole graph; Syntology's feed shows papers as they enter the graph.

Code

ai4healthuol/cardiolab officialmentioned in papermentioned on GitHubpytorchSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to CardioLab: Laboratory Values Estimation and Monitoring from Electrocardiogram Signals... (arXiv:2411.14886; that paper's own run record: 1 ran (of which 0 constructed an object rather than computing a result; 0 with no instrument failure: 0 honoured, 0 violated, 0 with no contract checked; 1 where Syntology's instrument failed) · 0 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Methods

SET

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections