Papers › Classifier Calibration at Scale: An Empirical Study of Model-Agnostic Post-Hoc Methods

Classifier Calibration at Scale: An Empirical Study of Model-Agnostic Post-Hoc Methods

19 Jan 2026arXiv:2601.19944added by Syntology

Valery Manokhin, Daniel Grønhaug

Title, abstract, authors and date from arXiv's metadata (CC0); this paper is not in the Papers with Code archive (frozen 2025-07-28).

We study model-agnostic post-hoc calibration methods intended to improve probabilistic predictions in supervised binary classification on real i.i.d. tabular data, with particular emphasis on conformal and Venn-based approaches that provide distribution-free validity guarantees under exchangeability. We benchmark 21 widely used classifiers, including linear models, SVMs, tree ensembles (CatBoost, XGBoost, LightGBM), and modern tabular neural and foundation models, on binary tasks from the TabArena-v0.1 suite using randomized, stratified five-fold cross-validation with a held-out test fold. Five calibrators; Isotonic regression, Platt scaling, Beta calibration, Venn-Abers predictors, and Pearsonify are trained on a separate calibration split and applied to test predictions. Calibration is evaluated using proper scoring rules (log-loss and Brier score) and diagnostic measures (Spiegelhalter's Z, ECE, and ECI), alongside discrimination (AUC-ROC) and standard classification metrics. Across tasks and architectures, Venn-Abers predictors achieve the largest average reductions in log-loss, followed closely by Beta calibration, while Platt scaling exhibits weaker and less consistent effects. Beta calibration improves log-loss most frequently across tasks, whereas Venn-Abers displays fewer instances of extreme degradation and slightly more instances of extreme improvement. Importantly, we find that commonly used calibration procedures, most notably Platt scaling and isotonic regression, can systematically degrade proper scoring performance for strong modern tabular models. Overall classification performance is often preserved, but calibration effects vary substantially across datasets and architectures, and no method dominates uniformly. In expectation, all methods except Pearsonify slightly increase accuracy, but the effect is marginal, with the largest expected gain about 0.008%.

PaperPDF

In Syntology Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

Code

valeman/classifier_calibration found in paper text by Syntology report

Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Syntology holds the repository link but has not harvested or run code from it.

Results from the paper

The Papers with Code archive ends with its 2025-07-28 snapshot. This paper's arXiv identifier, 2601.19944, was issued in January 2026, after that date, so the archive has no leaderboard rows for it.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections