Papers › A Physical Model for Microstructural Characterization and Segmentation of 3D Tomography Data

A Physical Model for Microstructural Characterization and Segmentation of 3D Tomography Data

15 Sep 2020arXiv:2009.07218links table onlyarchive 2025-07-28

Elise Otterlei Brenne, Vedrana Andersen Dahl, Peter Stanley Jørgensen

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

We present a novel method for characterizing the microstructure of a material from volumetric datasets such as 3D image data from computed tomography (CT). The method is based on a new statistical model for the distribution of voxel intensities and gradient magnitudes, incorporating prior knowledge about the physical nature of the imaging process. It allows for direct quantification of parameters of the imaged sample like volume fractions, interface areas and material density, and parameters related to the imaging process like image resolution and noise levels. Existing methods for characterization from 3D images often require segmentation of the data, a procedure where each voxel is labeled according to the best guess of which material it represents. Through our approach, the segmentation step is circumvented so that errors and computational costs related to this part of the image processing pipeline are avoided. Instead, the material parameters are quantified through their known relation to parameters of our model which is fitted directly to the raw, unsegmented data. We present an automated model fitting procedure that gives reproducible results without human bias and enables automatic analysis of large sets of tomograms. For more complex structure analysis questions, a segmentation is still beneficial. We show that our model can be used as input to existing probabilistic methods, providing a segmentation that is based on the physics of the imaged sample. Because our model accounts for mixed-material voxels stemming from blurring inherent to the imaging technique, we reduce the errors that other methods can create at interfaces between materials.

PaperPDFCode

Code

elobre/bimm officialmentioned in papermentioned on GitHubpytorch report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections