Papers › A Personalized Zero-Shot ECG Arrhythmia Monitoring System: From Sparse Representation...

A Personalized Zero-Shot ECG Arrhythmia Monitoring System: From Sparse Representation Based Domain Adaption to Energy Efficient Abnormal Beat Detection for Practical ECG Surveillance

14 Jul 2022arXiv:2207.07089archive 2025-07-28

Mehmet Yamaç, Mert Duman, İlke Adalıoğlu, Serkan Kiranyaz, Moncef Gabbouj

This paper proposes a low-cost and highly accurate ECG-monitoring system intended for personalized early arrhythmia detection for wearable mobile sensors. Earlier supervised approaches for personalized ECG monitoring require both abnormal and normal heartbeats for the training of the dedicated classifier. However, in a real-world scenario where the personalized algorithm is embedded in a wearable device, such training data is not available for healthy people with no cardiac disorder history. In this study, (i) we propose a null space analysis on the healthy signal space obtained via sparse dictionary learning, and investigate how a simple null space projection or alternatively regularized least squares-based classification methods can reduce the computational complexity, without sacrificing the detection accuracy, when compared to sparse representation-based classification. (ii) Then we introduce a sparse representation-based domain adaptation technique in order to project other existing users' abnormal and normal signals onto the new user's signal space, enabling us to train the dedicated classifier without having any abnormal heartbeat of the new user. Therefore, zero-shot learning can be achieved without the need for synthetic abnormal heartbeat generation. An extensive set of experiments performed on the benchmark MIT-BIH ECG dataset shows that when this domain adaptation-based training data generator is used with a simple 1-D CNN classifier, the method outperforms the prior work by a significant margin. (iii) Then, by combining (i) and (ii), we propose an ensemble classifier that further improves the performance. This approach for zero-shot arrhythmia detection achieves an average accuracy level of 98.2% and an F1-Score of 92.8%. Finally, a personalized energy-efficient ECG monitoring scheme is proposed using the above-mentioned innovations.

PaperPDFCode

Code

mertduman/zero-shot-ecg officialmentioned in papermentioned on GitHubpytorch report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Arrhythmia DetectionDictionary LearningDomain AdaptationECG ClassificationSparse Representation-based ClassificationZero-Shot Learning

Results from the paper archive 2025-07-28

TaskDatasetModelMetricValueRank at snapshotLeaderboardReport
Arrhythmia Detection MIT-BIH Arrhythmia Database Ensemble CNN Classifier with Domain Adaptation Accuracy 98.2 #2 of 2 Archive leaderboard report
Arrhythmia Detection MIT-BIH Arrhythmia Database Ensemble CNN Classifier with Domain Adaptation F1 92.8 #2 of 2 Archive leaderboard report
Arrhythmia Detection MIT-BIH Arrhythmia Database Ensemble CNN Classifier with Domain Adaptation Precision 91.9 #2 of 2 Archive leaderboard report
Arrhythmia Detection MIT-BIH Arrhythmia Database Ensemble CNN Classifier with Domain Adaptation Recall 93.7 #2 of 2 Archive leaderboard report
Arrhythmia Detection MIT-BIH Arrhythmia Database Ensemble CNN Classifier with Domain Adaptation specificity 98.8 #2 of 2 Archive leaderboard report

Ranks are positions in the archive's leaderboards as they stood at the 2025-07-28 snapshot. Results published since then are not among these rows, so a rank here is not a current standing.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections