Papers › A digital instrument simulator to optimize the development of hyperspectral systems:...

A digital instrument simulator to optimize the development of hyperspectral systems: application for intraoperative functional brain mapping

3 Jun 2024arXiv:2406.01217links table onlyarchive 2025-07-28

Charly Caredda, Frédéric Lange, Luca Giannoni, Ivan Ezhov, Thiébaud Picart, Jacques Guyotat, Ilias Tachtsidis, Bruno Montcel

The archive published only this paper's code-link row. Authors, date and abstract are from arXiv's metadata (CC0), read from the Kaggle arXiv metadata snapshot of 2026-09-12 where its title matched the archive's; the title is the archive's.

Intraoperative optical imaging is a localization technique for the functional areas of the human brain cortex during neurosurgical procedures. These areas can be assessed by monitoring cerebral hemodynamics and metabolism. A robust quantification of these biomarkers is complicated to perform during neurosurgery due to the critical context of the operating room. In actual devices, the inhomogeneities of the optical properties of exposed brain cortex are poorly taken into consideration, which introduce quantification errors of biomarkers of brain functionality. Moreover, the choice of the best spectral configuration is still based on an empirical approach. We propose a digital instrument simulator to optimize the development of hyperspectral systems. This simulator can provide a realistic modelling of the cerebral cortex and the identification of the optimal wavelengths to monitor cerebral hemodynamics (oxygenated and deoxygenated hemoglobin) and metabolism (oxidized state of cytochromes b, c and cytochrome-c-oxidase). The digital instrument allows the modelling of intensity maps collected by a camera sensor as well as images of pathlength to take into account the inhomogeneities of the optical properties. The optimization procedure helps to identify the best wavelength combination of 18 wavelengths that reduce the quantification errors in HbO2, Hb, oxCCO of 61%, 29% and 82% compared to the gold standard of 121 wavelengths between 780 and 900 nm. The optimization procedure does not help to resolve changes in cytochrome b and c in a significant way but help to better resolve oxCCO changes. We proposed a digital instrument simulator to optimize the development of hyperspectral systems for intraoperative brain mapping studies. This digital instrument simulator and this optimization framework could be used to optimize the design of hyperspectral imaging devices.

PaperPDFCode

Code

CCaredda/White-Monte-Carlo officialmentioned in paper report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections