Papers › A CNN-Based Blind Denoising Method for Endoscopic Images

A CNN-Based Blind Denoising Method for Endoscopic Images

16 Mar 2020Conference 2019 12arXiv:2003.06986archive 2025-07-28

Shaofeng Zou, Mingzhu Long, Xuyang Wang, Xiang Xie, Guolin Li, Zhihua Wang

The quality of images captured by wireless capsule endoscopy (WCE) is key for doctors to diagnose diseases of gastrointestinal (GI) tract. However, there exist many low-quality endoscopic images due to the limited illumination and complex environment in GI tract. After an enhancement process, the severe noise become an unacceptable problem. The noise varies with different cameras, GI tract environments and image enhancement. And the noise model is hard to be obtained. This paper proposes a convolutional blind denoising network for endoscopic images. We apply Deep Image Prior (DIP) method to reconstruct a clean image iteratively using a noisy image without a specific noise model and ground truth. Then we design a blind image quality assessment network based on MobileNet to estimate the quality of the reconstructed images. The estimated quality is used to stop the iterative operation in DIP method. The number of iterations is reduced about 36% by using transfer learning in our DIP process. Experimental results on endoscopic images and real-world noisy images demonstrate the superiority of our proposed method over the state-of-the-art methods in terms of visual quality and quantitative metrics.

PaperPDFCode

Syntology This paper's arXiv id is not in Syntology's Atlas id list (549,449 ids, as this build read them; the read time is in the build record), so this page links to no Syntology page for it. The list is not the whole graph; Syntology's feed shows papers as they enter the graph.

Code

ShaofengZou/A-CNN-Based-Blind-Denoising-Method pytorchSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to MobileNets: Efficient Convolutional Neural Networks for Mobile Vision Applications (arXiv:1704.04861; that paper's own run record: 53 ran (of which 28 constructed an object rather than computing a result; 44 with no instrument failure: 4 honoured, 0 violated, 40 with no contract checked; 9 where Syntology's instrument failed) · 30 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

DenoisingImage EnhancementImage Quality AssessmentNo-Reference Image Quality AssessmentTransfer Learning

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections