Datasets › Replication Data for: Assessment of a Cost-Effective Headphone Calibration Procedure for Soundscape Evaluations
Replication Data for: Assessment of a Cost-Effective Headphone Calibration Procedure for Soundscape Evaluations
This dataset contains the data used for all statistical comparisons in our ICSV 2022 submission "Assessment of a Cost-Effective Headphone Calibration Procedure for Soundscape Evaluations", summarised in a single .csv file.
To obtain the data in this dataset, 17 participants were invited to each rate 27 stimuli twice, once with the stimuli calibrated with a head-and-torso simulator ("HATS method") and once with the stimuli calibrated via an open-circuit voltage method ("OCV method"). This resulted in a total of 17272 = 918 data samples, corresponding to the number of rows in the .csv file.
For more details on the calibration method and listening test procedure, please refer to our manuscript:
B. Lam, K. Ooi, K.N. Watcharasupat, Y.-T. Lau, Z.-T. Ong, T. Wong, W.-S. Gan, "Assessment of a Cost-Effective Headphone Calibration Procedure for Soundscape Evaluations", in Proceedings of the 28th International Congress on Sound and Vibration, ICSV28, Singapore, 2022.
A short explanation of the columns in the .csv file is as follows:
calib_method: The method used to calibrate the stimulus for which the present row of responses was obtained (eitherHATSorOCV)participant_idx: The index of the participant who provided the present row of responses. Each participant is assigned a unique index. In addition, indices do not start from 1 because we omitted data from participants who adjusted volume settings when listening to the stimuli (thus rendering the calibration invalid), as well as participants who were unable to provide a complete set of responses for stimuli calibrated using both calibration methods.stimulus_idx: The index of the stimulus for which the present row of responses was obtained (integers from 1 to 27, inclusive).pleasant: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "pleasant".chaotic: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "chaotic"vibrant: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "vibrant"uneventful: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "uneventful"calm: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "calm"annoying: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "annoying"eventful: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "eventful"monotonous: The rating given by the participant for the present stimulus on a scale of 0 to 100 (inclusive) for the attribute "monotonous"
Benchmarks archive 2025-07-28
No leaderboard in the archive resolves to this dataset.
Papers archive 2025-07-28
No paper in the archive has a leaderboard row on this dataset; the archive counts 1 paper for it but never published that list.
Dataset loaders archive 2025-07-28
No loader listed in the archive.
Tasks archive 2025-07-28
No task tagged in the archive.
License archive 2025-07-28
Modalities archive 2025-07-28
No modality tagged.
Languages archive 2025-07-28
No language tagged.
Variants archive 2025-07-28
- Replication Data for: Assessment of a Cost-Effective Headphone Calibration Procedure for Soundscape Evaluations
1 variant name, as the archive lists them.
Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections