Datasets › PTB Diagnostic ECG Database
PTB Diagnostic ECG Database
The ECGs in this collection were obtained using a non-commercial, PTB prototype recorder with the following specifications:
16 input channels, (14 for ECGs, 1 for respiration, 1 for line voltage) Input voltage: ±16 mV, compensated offset voltage up to ± 300 mV Input resistance: 100 Ω (DC) Resolution: 16 bit with 0.5 μV/LSB (2000 A/D units per mV) Bandwidth: 0 - 1 kHz (synchronous sampling of all channels) Noise voltage: max. 10 μV (pp), respectively 3 μV (RMS) with input short circuit Online recording of skin resistance Noise level recording during signal collection The database contains 549 records from 290 subjects (aged 17 to 87, mean 57.2; 209 men, mean age 55.5, and 81 women, mean age 61.6; ages were not recorded for 1 female and 14 male subjects). Each subject is represented by one to five records. There are no subjects numbered 124, 132, 134, or 161. Each record includes 15 simultaneously measured signals: the conventional 12 leads (i, ii, iii, avr, avl, avf, v1, v2, v3, v4, v5, v6) together with the 3 Frank lead ECGs (vx, vy, vz). Each signal is digitized at 1000 samples per second, with 16 bit resolution over a range of ± 16.384 mV. On special request to the contributors of the database, recordings may be available at sampling rates up to 10 KHz.
Within the header (.hea) file of most of these ECG records is a detailed clinical summary, including age, gender, diagnosis, and where applicable, data on medical history, medication and interventions, coronary artery pathology, ventriculography, echocardiography, and hemodynamics. The clinical summary is not available for 22 subjects.
Source: PTB
Benchmarks archive 2025-07-28
All 4 leaderboards whose dataset resolves to this page shown (sort by any header). "First row" is the archive's own first row at snapshot, in the archive's row order; nothing here re-ranks and metric direction is not asserted.
| First row (archive order) | Paper | Code | ||||
|---|---|---|---|---|---|---|
| Constituency Grammar Induction | PTB Diagnostic ECG Database | Ensemble (Generative MBR) Mean F1 (WSJ) 70.4 | Ensemble Distillation for Unsupervised Constituency Parsing | manga-uofa/ed4ucp | 24 | Compare |
| ECG Patient Identification (gallery-probe) | PTB Diagnostic ECG Database | ElectroCardioGuard Accuracy 77.0% | ElectroCardioGuard: Preventing Patient Misidentification... | captaintrojan/electrocardioguard | 1 | Compare |
| Language Modelling | PTB Diagnostic ECG Database | I-DARTS PPL 56.0 | Improved Differentiable Architecture Search for Language... | jiangyingjunn/i-darts | 1 | Compare |
| Myocardial infarction detection | PTB Diagnostic ECG Database | ConvNetQuake Accuracy (%) 99.43% | Deep Learning for Cardiologist-level Myocardial... | arjung128/mi_detection | 1 | Compare |
Papers archive 2025-07-28
papers with a benchmark row: 21 · with a code link: 20 · where Syntology ran a sample: 8 (6 with a run with no instrument failure, 2 where every run was a failure of Syntology's instrument) Syntology
Show: all papers with a benchmark rowonly where code ran (8 of 21 with a benchmark row: 6 with a run with no instrument failure, 2 where every run was a failure of Syntology's instrument)
Page 1 of 1: papers 1 to 21 of 21 with a leaderboard row on this dataset's benchmarks, newest first by the archive's date (ties by slug; undated papers last).
The archive's own "papers using this dataset" list was never published, so this is the benchmark-backed subset, not that list; the archive's count for this dataset is 22. The Syntology column is from Syntology's graph, stated per sample; it is not part of any archive number. A line reads “N ran (of which C constructed an object rather than computing a result; K with no instrument failure: H honoured, V violated, P with no contract checked; I where Syntology's instrument failed) · U unverified” (C is a part of N, never taken away from it); the figure “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. “Ran” means the sample executed on a synthesized fixture, not that the paper's result was reproduced. When the archive marks a repository official for the paper, the cell starts with that repository's state (the archive's flag, not a verdict on who wrote the code; “community repositories only” when every sample that ran came from a community repository, “official: no sample here; runs from other or unrecorded repositories” when some came from a repository the paper names or has in its text, or from none recorded); hover it for the repositories the samples that ran came from. Syntology's record for this page last changed ; when this build read Syntology's graph is in the build record.
Dataset loaders archive 2025-07-28
No loader listed in the archive.
Tasks archive 2025-07-28
License archive 2025-07-28
Open Data Commons Attribution License v1.0
Modalities archive 2025-07-28
Languages archive 2025-07-28
Variants archive 2025-07-28
- PTB Diagnostic ECG Database
1 variant name, as the archive lists them.
Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections