Datasets › CBIS-DDSM

CBIS-DDSM (Curated Breast Imaging Subset of Digital Database for Screening Mammography)

19 Dec 2017 archive 2025-07-28

This CBIS-DDSM (Curated Breast Imaging Subset of DDSM) is an updated and standardized version of the Digital Database for Screening Mammography (DDSM) . The DDSM is a database of 2,620 scanned film mammography studies. It contains normal, benign, and malignant cases with verified pathology information. The scale of the database along with ground truth validation makes the DDSM a useful tool in the development and testing of decision support systems. The CBIS-DDSM collection includes a subset of the DDSM data selected and curated by a trained mammographer. The images have been decompressed and converted to DICOM format. Updated ROI segmentation and bounding boxes, and pathologic diagnosis for training data are also included. A manuscript describing how to use this dataset in detail is available at https://www.nature.com/articles/sdata2017177.

Published research results from work in developing decision support systems in mammography are difficult to replicate due to the lack of a standard evaluation data set; most computer-aided diagnosis (CADx) and detection (CADe) algorithms for breast cancer in mammography are evaluated on private data sets or on unspecified subsets of public databases. Few well-curated public datasets have been provided for the mammography community. These include the DDSM, the Mammographic Imaging Analysis Society (MIAS) database, and the Image Retrieval in Medical Applications (IRMA) project. Although these public data sets are useful, they are limited in terms of data set size and accessibility.

For example, most researchers using the DDSM do not leverage all its images for a variety of historical reasons. When the database was released in 1997, computational resources to process hundreds or thousands of images were not widely available. Additionally, the DDSM images are saved in non-standard compression files that require the use of decompression code that has not been updated or maintained for modern computers. Finally, the ROI annotations for the abnormalities in the DDSM were provided to indicate a general position of lesions, but not a precise segmentation for them. Therefore, many researchers must implement segmentation algorithms for accurate feature extraction. This causes an inability to directly compare the performance of methods or to replicate prior results. The CBIS-DDSM collection addresses that challenge by publicly releasing an curated and standardized version of the DDSM for evaluation of future CADx and CADe systems (sometimes referred to generally as CAD) research in mammography.

Please note that the image data for this collection is structured such that each participant has multiple patient IDs. For example, participant 00038 has 10 separate patient IDs which provide information about the scans within the IDs (e.g. Calc-Test_P_00038_LEFT_CC, Calc-Test_P_00038_RIGHT_CC_1). This makes it appear as though there are 6,671 patients according to the DICOM metadata, but there are only 1,566 actual participants in the cohort.

Benchmarks archive 2025-07-28

All 2 leaderboards whose dataset resolves to this page shown (sort by any header). "First row" is the archive's own first row at snapshot, in the archive's row order; nothing here re-ranks and metric direction is not asserted.

Syntology 1 newer paper was judged to report on this dataset's benchmarks so far (Claude Sonnet 4.5, reading their tables: a model's judgement, not a result; 0 placed): Cancer-no cancer per image classification · CBIS-DDSM (1 judged, 0 placed). Drawn from 8,886 of 18,637 newer papers checked so far (733 more had nothing to place; 41 could not be read).

First row (archive order)PaperCode
Cancer-no cancer per image classification CBIS-DDSM Multi-patch size DenseNet-121 AUC 0.809 Exploiting Patch Sizes and Resolutions for Multi-Scale... — 16 Compare
Cancer-no cancer per breast classification CBIS-DDSM EfficientNet-B0 w/ TTA AUC 0.8483 Breast Cancer Diagnosis in Two-View Mammography Using... dpetrini/two-views-classifier 3 Compare

Papers archive 2025-07-28

papers with a benchmark row: 6 · with a code link: 3 · where Syntology ran a sample: 1 (1 with a run with no instrument failure, 0 where every run was a failure of Syntology's instrument) Syntology

Show: all papers with a benchmark rowonly where code ran (1 of 6 with a benchmark row: 1 with a run with no instrument failure, 0 where every run was a failure of Syntology's instrument)

Page 1 of 1: papers 1 to 6 of 6 with a leaderboard row on this dataset's benchmarks, newest first by the archive's date (ties by slug; undated papers last).

The archive's own "papers using this dataset" list was never published, so this is the benchmark-backed subset, not that list; the archive's count for this dataset is 13. The Syntology column is from Syntology's graph, stated per sample; it is not part of any archive number. A line reads “N ran (of which C constructed an object rather than computing a result; K with no instrument failure: H honoured, V violated, P with no contract checked; I where Syntology's instrument failed) · U unverified” (C is a part of N, never taken away from it); the figure “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. “Ran” means the sample executed on a synthesized fixture, not that the paper's result was reproduced. When the archive marks a repository official for the paper, the cell starts with that repository's state (the archive's flag, not a verdict on who wrote the code; “community repositories only” when every sample that ran came from a community repository, “official: no sample here; runs from other or unrecorded repositories” when some came from a repository the paper names or has in its text, or from none recorded); hover it for the repositories the samples that ran came from. Syntology's record for this page last changed ; when this build read Syntology's graph is in the build record.

Dataset loaders archive 2025-07-28

1 loader as listed in the archive; links are outbound and not re-checked here.

Tasks archive 2025-07-28

License archive 2025-07-28

CC BY-SA 3.0

Modalities archive 2025-07-28

Languages archive 2025-07-28

No language tagged.

Variants archive 2025-07-28

  • CBIS-DDSM

1 variant name, as the archive lists them.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections