{"about":{"site":"https://codewithpapers.app","non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page"},"url":"/paper/per-pixel-lung-thickness-and-lung-capacity","title":"Estimating Total Lung Volume from Pixel-level Thickness Maps of Chest Radiographs Using Deep Learning","arxiv_id":"2110.12509","date":"2021-10-24","proceeding":null,"authors":["Tina Dorosti","Manuel Schultheiss","Philipp Schmette","Jule Heuchert","Johannes Thalhammer","Florian T. Gassert","Thorsten Sellerer","Rafael Schick","Kirsten Taphorn","Korbinian Mechlem","Lorenz Birnbacher","Florian Schaff","Franz Pfeiffer","Daniela Pfeiffer"],"abstract":"Purpose: To estimate the total lung volume (TLV) from real and synthetic frontal chest radiographs (CXR) on a pixel level using lung thickness maps generated by a U-Net deep learning model. Methods: This retrospective study included 5,959 chest CT scans from two public datasets: the lung nodule analysis 2016 (n=656) and the Radiological Society of North America (RSNA) pulmonary embolism detection challenge 2020 (n=5,303). Additionally, 72 participants were selected from the Klinikum Rechts der Isar dataset (October 2018 to December 2019), each with a corresponding chest radiograph taken within seven days. Synthetic radiographs and lung thickness maps were generated using forward projection of CT scans and their lung segmentations. A U-Net model was trained on synthetic radiographs to predict lung thickness maps and estimate TLV. Model performance was assessed using mean squared error (MSE), Pearson correlation coefficient (r), and two-sided Student's t-distribution. Results: The study included 72 participants (45 male, 27 female, 33 healthy: mean age 62 years [range 34-80]; 39 with chronic obstructive pulmonary disease: mean age 69 years [range 47-91]). TLV predictions showed low error rates ($MSE_{Public-Synthetic}$=0.16 $L^2$, $MSE_{KRI-Synthetic}$=0.20 $L^2$, $MSE_{KRI-Real}$=0.35 $L^2$) and strong correlations with CT-derived reference standard TLV ($n_{Public-Synthetic}$=1,191, r=0.99, P<0.001; $n_{KRI-Synthetic}$=72, r=0.97, P<0.001; $n_{KRI-Real}$=72, r=0.91, P<0.001). The Luna16 test data demonstrated the highest performance, with the lowest mean squared error (MSE = 0.09 $L^2$) and strongest correlation (r = 0.99, P <0.001) for TLV estimation. Conclusion: The U-Net-generated pixel-level lung thickness maps successfully estimated TLV for both synthetic and real radiographs.","url_abs":"https://arxiv.org/abs/2110.12509v6","url_pdf":"https://arxiv.org/pdf/2110.12509v6.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"per-pixel-lung-thickness-and-lung-capacity","repo_url":"https://github.com/tidorosti/lungthickness","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"tf","reach":null}],"tasks":[{"task_slug":"capacity-estimation","task_name":"Capacity Estimation"},{"task_slug":"pulmonary-embolism-detection","task_name":"Pulmonary Embolism Detection"}],"methods":[{"method_slug":"test","method_name":"Test"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers"},"arxiv_metadata":null,"syntology_extracted_results":null}