{"about":{"site":"https://codewithpapers.app","non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page"},"url":"/paper/active-mr-k-space-sampling-with-reinforcement","title":"Active MR k-space Sampling with Reinforcement Learning","arxiv_id":"2007.10469","date":"2020-07-20","proceeding":null,"authors":["Luis Pineda","Sumana Basu","Adriana Romero","Roberto Calandra","Michal Drozdzal"],"abstract":"Deep learning approaches have recently shown great promise in accelerating magnetic resonance image (MRI) acquisition. The majority of existing work have focused on designing better reconstruction models given a pre-determined acquisition trajectory, ignoring the question of trajectory optimization. In this paper, we focus on learning acquisition trajectories given a fixed image reconstruction model. We formulate the problem as a sequential decision process and propose the use of reinforcement learning to solve it. Experiments on a large scale public MRI dataset of knees show that our proposed models significantly outperform the state-of-the-art in active MRI acquisition, over a large range of acceleration factors.","url_abs":"https://arxiv.org/abs/2007.10469v2","url_pdf":"https://arxiv.org/pdf/2007.10469v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"active-mr-k-space-sampling-with-reinforcement","repo_url":"https://github.com/facebookresearch/active-mri-acquisition","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":{"status":"ok","spdx":"MIT"}},{"paper_slug":"active-mr-k-space-sampling-with-reinforcement","repo_url":"https://github.com/facebookresearch/fastMRI","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"image-reconstruction","task_name":"Image Reconstruction"},{"task_slug":"reinforcement-learning","task_name":"Reinforcement Learning"},{"task_slug":"reinforcement-learning-1","task_name":"Reinforcement Learning (RL)"},{"task_slug":"reinforcement-learning-2","task_name":"reinforcement-learning"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"atlas_url":"https://app.syntology.ai/?focus=2007.10469","mcp":{"get_harvested_code_for_paper":{"arxiv_id":"2007.10469"}},"developers":"https://syntology.ai/developers","read_at":"2026-09-24T18:15:14+00:00","read_at_is":"when the build read Syntology's graph, not when any sample ran","claim":"Per-sample execution status on synthesized fixtures; not a correctness claim about the paper. Samples come from repositories linked to the paper, official or community; repo_kind says which.","repos":[{"provenance":"external:paperswithcode_snapshot_2025-07-28","url":"https://github.com/facebookresearch/active-mri-acquisition","reach":{"status":"ok","spdx":"MIT"}},{"provenance":"external:paperswithcode_snapshot_2025-07-28","url":"https://github.com/facebookresearch/fastMRI","reach":null}],"summary":{"unverified":6},"by_repo_kind":{"official":{"samples":6,"ran":0,"repositories":1}},"repo_kind_vocabulary":{"official":"The archive marks this repository official for the paper","named_in_paper":"The archive records that the paper mentions this repository; it is not marked official","listed":"In the archive's code links for this paper, not marked official and not recorded as mentioned in the paper","found_in_text":"Syntology found this repository in the paper's own text; whether it is the authors' implementation is not asserted","community":"Not in the archive's code links for this paper; a community repository Syntology harvested"},"n_pointer_only_for_licence":1,"samples":[{"code_sha256_prefix":"4d1985323982489e","entry":"check_masks_complete","repo":"facebookresearch/active-mri-acquisition","repo_kind":"official","path":"activemri/envs/masks.py","file_url":"https://github.com/facebookresearch/active-mri-acquisition/blob/HEAD/activemri/envs/masks.py","link_basis":"plan_row","language":"python","status":"unverified","verification_level":0,"contract_check":null,"metamorphic_tier":null,"behaviour_fingerprint":false,"licence":"MIT","inline_ok":true,"mcp_get_code":{"code_sha256":"4d1985323982489e"}},{"code_sha256_prefix":"818735d3069334bf","entry":"compute_psnr","repo":"facebookresearch/active-mri-acquisition","repo_kind":"official","path":"activemri/envs/util.py","file_url":"https://github.com/facebookresearch/active-mri-acquisition/blob/HEAD/activemri/envs/util.py","link_basis":"plan_row","language":"python","status":"unverified","verification_level":0,"contract_check":null,"metamorphic_tier":null,"behaviour_fingerprint":false,"licence":"MIT","inline_ok":true,"mcp_get_code":{"code_sha256":"818735d3069334bf"}},{"code_sha256_prefix":"cd25081a4c499255","entry":"compute_ssim","repo":"facebookresearch/active-mri-acquisition","repo_kind":"official","path":"activemri/envs/util.py","file_url":"https://github.com/facebookresearch/active-mri-acquisition/blob/HEAD/activemri/envs/util.py","link_basis":"plan_row","language":"python","status":"unverified","verification_level":0,"contract_check":null,"metamorphic_tier":null,"behaviour_fingerprint":false,"licence":"MIT","inline_ok":true,"mcp_get_code":{"code_sha256":"cd25081a4c499255"}},{"code_sha256_prefix":"939a9acd64cf6672","entry":"import_object_from_str","repo":"facebookresearch/active-mri-acquisition","repo_kind":"official","path":"activemri/envs/util.py","file_url":"https://github.com/facebookresearch/active-mri-acquisition/blob/HEAD/activemri/envs/util.py","link_basis":"plan_row","language":"python","status":"unverified","verification_level":0,"contract_check":null,"metamorphic_tier":null,"behaviour_fingerprint":false,"licence":"MIT","inline_ok":true,"mcp_get_code":{"code_sha256":"939a9acd64cf6672"}},{"code_sha256_prefix":"c579bc5ee3c1f0ff","entry":"save_checkpoint_function","repo":"facebookresearch/active-mri-acquisition","repo_kind":"official","path":"activemri/experimental/cvpr19_models/trainer.py","file_url":"https://github.com/facebookresearch/active-mri-acquisition/blob/HEAD/activemri/experimental/cvpr19_models/trainer.py","link_basis":"first_harvest_node","language":"python","status":"unverified","verification_level":0,"contract_check":null,"metamorphic_tier":null,"behaviour_fingerprint":false,"licence":"MIT","inline_ok":false,"mcp_get_code":{"code_sha256":"c579bc5ee3c1f0ff"}},{"code_sha256_prefix":"09b91568694b7508","entry":"update_masks_from_indices","repo":"facebookresearch/active-mri-acquisition","repo_kind":"official","path":"activemri/envs/masks.py","file_url":"https://github.com/facebookresearch/active-mri-acquisition/blob/HEAD/activemri/envs/masks.py","link_basis":"plan_row","language":"python","status":"unverified","verification_level":0,"contract_check":null,"metamorphic_tier":null,"behaviour_fingerprint":false,"licence":"MIT","inline_ok":true,"mcp_get_code":{"code_sha256":"09b91568694b7508"}}]},"arxiv_metadata":null,"syntology_extracted_results":null}